« Previous
Next »
Ophthalmology
Volume 115, Issue 3
, Pages 566-572.e2
, March 2008
Exposure Rate of Hydroxyapatite Orbital Implants: A 15-Year Experience of 802 Cases
References
- . Integrated orbital implants. Adv Ophthalmic Plast Reconstr Surg. 1990;8:75–81
- . Coralline hydroxyapatite as an ocular implant. Ophthalmology. 1991;98:370–377
- . Lack of complications of the hydroxyapatite orbital implant in 250 consecutive cases. Trans Am Ophthalmol Soc. 1993;91:177–189
- Complications of porous spherical orbital implants. Ophthalmology. 1995;102:586–593
- . Tissue breakdown and exposure associated with orbital hydroxyapatite implants. Am J Ophthalmol. 1992;113:669–673
- Exposure rate of hydroxyapatite spheres in the anophthalmic socket: histopathologic correlation and comparison with silicone sphere implants. Ophthal Plast Reconstr Surg. 1993;9:96–104
- . Coralline hydroxyapatite orbital implant (Bio-Eye): experience with 158 patients. Ophthal Plast Reconstr Surg. 2004;20:69–74
- . Problems after evisceration surgery with porous orbital implants: experience with 86 patients. Ophthal Plast Reconstr Surg. 2004;20:374–380
- . Current trends in managing the anophthalmic socket after primary enucleation and evisceration. Ophthal Plast Reconstr Surg. 2004;20:274–280
- Modification of the scleral openings to reduce tissue breakdown and exposure after hydroxyapatite implantations. Ophthalmologica. 1995;209:319–322
- . Comparative motility of hydroxyapatite and alloplastic enucleation implants. Ophthalmology. 1999;106:513–516
- . Predicting the ideal implant size before enucleation. Ophthal Plast Reconstr Surg. 1999;15:37–43
- Complications in motility peg placement for hydroxyapatite orbital implant in anophthalmic socket. Jpn J Ophthalmol. 2002;46:103–107
- Intraorbital implants after enucleation and their complications: a 10-year review. Arch Ophthalmol. 1998;116:1199–1203
- . Bovine pericardium versus homologous sclera as a wrapping for hydroxyapatite orbital implants. Ophthal Plast Reconstr Surg. 2003;19:189–193
- . Human dura mater as a wrapping material for hydroxyapatite implantation in the anophthalmic socket. Ophthalmic Surg Lasers. 1997;28:428–431
- Creutzfeldt-Jakob disease associated with cadaveric dura mater grafts in Japan. Neurology. 2000;55:718–721
- . Complications of hydroxyapatite orbital implants: a review of 100 consecutive cases and a comparison of Dexon mesh (polyglycolic acid) with scleral wrapping. Ophthalmology. 1997;104:324–329
- The use of Vicryl mesh (polyglactin 910) for implantation of hydroxyapatite orbital implants. Ophthal Plast Reconstr Surg. 1995;11:95–99
- . The use of vicryl mesh in 200 porous orbital implants: a technique with few exposures. Ophthal Plast Reconstr Surg. 2003;19:53–61
- . A comparison of rates of fibrovascular ingrowth in wrapped versus unwrapped hydroxyapatite spheres in a rabbit model. Ophthal Plast Reconstr Surg. 2002;18:275–280
- Vicryl-mesh wrap for the implantation of hydroxyapatite orbital implants: an animal model. Can J Ophthalmol. 1995;30:241–246
- Exposure of orbital implants wrapped with polyester-urethane after enucleation for advanced retinoblastoma. Ophthal Plast Reconstr Surg. 2005;21:123–128
- . Management of exposed hydroxyapatite orbital implants. Ophthalmology. 1994;101:1709–1715
- . Current techniques of enucleation: a survey of 5,439 intraorbital implants and a review of the literature. Ophthal Plast Reconstr Surg. 1995;11:77–86
- . A new titanium peg system for hydroxyapatite orbital implants. Ophthal Plast Reconstr Surg. 2000;16:380–387
The authors have no commercial or proprietary interest in the products or companies mentioned in the article.
Manuscript no. 2007-110.
PII: S0161-6420(07)00666-5
doi: 10.1016/j.ophtha.2007.06.014
© 2008 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.
« Previous
Next »
Ophthalmology
Volume 115, Issue 3
, Pages 566-572.e2
, March 2008