Ophthalmology
Volume 117, Issue 9 , Pages 1692-1699.e1, September 2010

Comparison of Different Spectral Domain Optical Coherence Tomography Scanning Areas for Glaucoma Diagnosis

  • Harsha L. Rao, MD, DNB

      Affiliations

    • Hamilton Glaucoma Center, Department of Ophthalmology, University of California San Diego, La Jolla, California
    • L V Prasad Eye Institute, Banjara Hills, Hyderabad, India
  • ,
  • Linda M. Zangwill, PhD

      Affiliations

    • Hamilton Glaucoma Center, Department of Ophthalmology, University of California San Diego, La Jolla, California
  • ,
  • Robert N. Weinreb, MD

      Affiliations

    • Hamilton Glaucoma Center, Department of Ophthalmology, University of California San Diego, La Jolla, California
  • ,
  • Pamela A. Sample, PhD

      Affiliations

    • Hamilton Glaucoma Center, Department of Ophthalmology, University of California San Diego, La Jolla, California
  • ,
  • Luciana M. Alencar, MD

      Affiliations

    • Hamilton Glaucoma Center, Department of Ophthalmology, University of California San Diego, La Jolla, California
    • Department of Ophthalmology, University of São Paulo, São Paulo, SP, Brazil
  • ,
  • Felipe A. Medeiros, MD, PhD

      Affiliations

    • Hamilton Glaucoma Center, Department of Ophthalmology, University of California San Diego, La Jolla, California
    • Corresponding Author InformationCorrespondence: Felipe A. Medeiros, Hamilton Glaucoma Center, University of California, San Diego, 9500 Gilman Drive, La Jolla, CA 92093-0946

Received 15 September 2009; received in revised form 14 January 2010; accepted 15 January 2010. published online 20 May 2010.

Available online: May 20, 2010.

Purpose

To evaluate retinal nerve fiber layer (RNFL), optic nerve head (ONH), and macular thickness measurements for glaucoma detection using the RTVue spectral domain optical coherence tomograph.

Design

Diagnostic, case-control study.

Participants

One hundred forty eyes of 106 glaucoma patients and 74 eyes of 40 healthy subjects from the Diagnostic Innovations in Glaucoma Study (DIGS).

Methods

All patients underwent ocular imaging with the commercially available RTVue. Optic nerve head, RNFL thickness, and macular thickness scans were obtained during the same visit. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% and 95%) were calculated for each parameter.

Main Outcome Measures

Areas under the ROC curves (AUC) and sensitivities at fixed specificities of 80% and 95%.

Results

The AUC for the RNFL parameter with best performance, inferior quadrant thickness, was significantly higher than that of the best-performing ONH parameter, inferior rim area (0.884 vs 0.812, respectively; P = 0.04). There was no difference between ROC curve areas of the best RNFL thickness parameters and the best inner macular thickness measurement, ganglion cell complex root mean square (ROC curve area = 0.870).

Conclusions

The RTVue RNFL and inner retinal macular thickness measurements had good ability to detect eyes with glaucomatous visual field loss and performed significantly better than ONH parameters.

Financial Disclosure(s)

Proprietary or commercial disclosure may be found after the references.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

 Manuscript no. 2009-1274.

 Financial Disclosure(s): Linda M. Zangwill – Grant/Financial Support - Heidelberg Engineering, Carl Zeiss, OptovueRobert N. Weinreb – Consultant, Grant/Financial Support - Optovue, Topcon, Carl Zeiss; Grant/Financial Support - Heidelberg EngineeringPamela A. Sample – Grant/Financial Support - Carl Zeiss, Heidelberg Engineering, Welch AllynFelipe A. Medeiros – Consultant, Grant/Financial Support - Carl Zeiss; Lecture Fees - Heidelberg Engineering

 Supported in part by NEI EY08208 (PAS), NEI EY11008 (LMZ), Participant retention incentive grants in the form of glaucoma medication at no cost (Alcon Laboratories Inc., Allergan, Pfizer Inc., SANTEN Inc.).

PII: S0161-6420(10)00060-6

doi:10.1016/j.ophtha.2010.01.031

Ophthalmology
Volume 117, Issue 9 , Pages 1692-1699.e1, September 2010